167 research outputs found

    An analysis of the rhetoric used by Mormon women to argue equal suffrage in Utah : 1870-1896

    Get PDF
    Thesis (M.A.)--University of Kansas, Speech and Drama, 1973

    Framing in design: A formal analysis and failure modes

    Full text link
    This contribution presents a formal description of the design practice of framing and identifies two general modes in which framing can lead to failure in design projects. The first is called the goal reformulation failure mode and occurs when designers reformulate the goal of the client in a design task and give design solutions that solve the reformulated goal but not the original goal. The second is called the frame failure mode and occurs when designers propose a frame for the design task that cannot be accepted by the client. The analysis of framing and its failure modes is aimed at better understanding this design practice and provides a first step towards arriving at criteria that successful applications of framing should meet. The description and the failure modes are illustrated by critically considering an initially successful case of framing, namely the redesign of the Kings Cross entertainment district in Sydney

    Designing meaningful products in the digital age: How users value their technological possessions

    Full text link
    © 2019 Association for Computing Machinery. Devices such as phones, laptops and tablets have become central to the ways in which many people communicate with others, conduct business and spend their leisure time. This type of product uniquely contains both physical and digital components that affect how they are perceived and valued by users. This article investigates the nature of attachment in the context of technological possessions to better understand ways in which designers can create devices that are meaningful and kept for longer. Findings from our study of the self-reported associations and meaningfulness of technological possessions revealed that the digital contents of these possessions were often the primary source of meaning. Technological possessions were frequently perceived as systems of products rather than as singular devices. We identified several design opportunities for materialising the associations ascribed to the digital information contained within technological products to more meaningfully integrate their physical and digital components

    Bedded Pack Management System Case Study

    Get PDF
    Agribusiness, Agricultural Finance, Farm Management,

    Light Emitting Diodes as a Rapid Visual Display for Use in Psychological Experiments

    Full text link
    In this paper we show how light emitting diodes (LEDs) can be used in conjunction with existing display technologies as a means for achieving ultra-rapid visual stimulus exposure durations. We review existing rapid visual display meth-ods, and show how our apparatus overcomes the limitations inherent with each technique. Our apparatus, the LED tach-istoscope, takes advantage of the fast-switching times and high-brightness capabilities of LEDs in order to present sti- muli at previously unachievable durations as rapid as 1 ms. The rapid exposure durations are achieved by external LED backlight illumination of images on a liquid crystal display (LCD) after the components of the LCD have stabilized. This ensures that stimulus onset and offset are discrete. Furthermore, the fast-switching of the LEDs enables stimuli to be revealed for very rapid durations. The paper also describes studies in which the LED tachistoscope has already been applied, and offers suggestions for other possible applications. Interestingly, in our studies we show that the human visual system is very adept at extracting information with only very minimal stimulus exposure durations. Such studies have not been possible with existing display equipment. The LED tachistoscope opens up avenues for a variety of psy-chological and physiological experiments and provides a means for revealing the limits of human visual perception

    An automated optofluidic biosensor platform combining interferometric sensors and injection moulded microfluidics

    Get PDF
    A primary limitation preventing practical implementation of photonic biosensors within point-of-care platforms is their integration with fluidic automation subsystems. For most diagnostic applications, photonic biosensors require complex fluid handling protocols; this is especially prominent in the case of competitive immunoassays, commonly used for detection of low-concentration, low-molecular weight biomarkers. For this reason, complex automated microfluidic systems are needed to realise the full point-of-care potential of photonic biosensors. To fulfil this requirement, we propose an on-chip valve-based microfluidic automation module, capable of automating such complex fluid handling. This module is realised through application of a PDMS injection moulding fabrication technique, recently described in our previous work, which enables practical fabrication of normally closed pneumatically actuated elastomeric valves. In this work, these valves are configured to achieve multiplexed reagent addressing for an on-chip diaphragm pump, providing the sample and reagent processing capabilities required for automation of cyclic competitive immunoassays. Application of this technique simplifies fabrication and introduces the potential for mass production, bringing point-of-care integration of complex automated microfluidics into the realm of practicality. This module is integrated with a highly sensitive, label-free bimodal waveguide photonic biosensor, and is demonstrated in the context of a proof-of-concept biosensing assay, detecting the low-molecular weight antibiotic tetracycline

    Randomised trials comparing different healthcare settings : an exploratory review of the impact of pre-trial preferences on participation, and discussion of other methodological challenges

    Get PDF
    BACKGROUND: We recently published a systematic review of different healthcare settings (such as outpatient, community or home) for administering intravenous chemotherapy, and concluded that performing conventionally designed randomised trials was difficult. The main problems were achieving adequate trial accrual rates and recruiting a study population which adequately represented the target population of interest. These issues stemmed from the fact that potential participants may have had pre-trial perceptions about the trial settings they may be allocated; such preferences will sometimes be strong enough for patients to decline an invitation to participate in a trial. A patient preference trial design (in which patients can choose, or be randomised to, an intervention) may have obviated these recruitment issues, although none of the trials used such a design. METHODS: In order to gain a better understanding of the broader prevalence and extent of these preference issues (and any other methodological challenges), we undertook an exploratory review of settings trials in any area of healthcare treatment research. We searched The Cochrane Library and Google Scholar and used snowballing methods to identify trials comparing different healthcare settings. RESULTS: Trial accrual was affected by patient preferences for a setting in 15 of the 16 identified studies; birth setting trials were the most markedly affected, with between 68 % and 85 % of eligible women declining to participate specifically because of preference for a particular healthcare setting. Recruitment into substance abuse and chemotherapy setting studies was also notably affected by preferences. Only four trials used a preference design: the proportion of eligible patients choosing to participate via a preference group ranged from between 33 % and 67 %. CONCLUSIONS: In trials of healthcare settings, accrual may be seriously affected by patient preferences. The use of trial designs which incorporate a preference component should therefore strongly be considered. When designing such trials, investigators should consider settings to be complex interventions, which are likely to have linked components which may be difficult to control for. Careful thought is also needed regarding the choice of comparator settings and the most appropriate outcome measures to be used

    “There are things I want to say but you do not ask”: a comparison between standardised and individualised evaluations in substance use treatment

    Get PDF
    There has been an increasing call for service users to be more actively involved with the evaluation of treatment outcomes. One strategy to impove such involvement is to ask service users to contribute with their own criteria for evaluation by sharing their personal story and perspective about their clinical situation. In this cross-sectional study, we contrasted the contents elicited by service users completing two individualised measures against the contents of three widely used standardised measures. We also compared two methods to generate individualised data using self-report and interview-based instruments (PSYCHLOPS and PQ). Following a thematic comparison approach, we found that one quarter of the problems reported by patients in individualised measures were not covered by any of our standardised comparators. Also, half of our sample generated at least one problem whose theme was not covered by any of the three standardised measures. We also found that patients in this population have many other concerns beyond drug use. These included psychological (e.g. interpersonal relationships) and socio-economic (e.g. money) problems, which were frequently reported. Our study suggests that listening to service users’ stories allows us to capture issues of importance to service users in substance use treatment, which may be underestimated by standardised measures

    Three-Wall Segment (TriSeg) Model Describing Mechanics and Hemodynamics of Ventricular Interaction

    Get PDF
    A mathematical model (TriSeg model) of ventricular mechanics incorporating mechanical interaction of the left and right ventricular free walls and the interventricular septum is presented. Global left and right ventricular pump mechanics were related to representative myofiber mechanics in the three ventricular walls, satisfying the principle of conservation of energy. The walls were mechanically coupled satisfying tensile force equilibrium in the junction. Wall sizes and masses were rendered by adaptation to normalize mechanical myofiber load to physiological standard levels. The TriSeg model was implemented in the previously published lumped closed-loop CircAdapt model of heart and circulation. Simulation results of cardiac mechanics and hemodynamics during normal ventricular loading, acute pulmonary hypertension, and chronic pulmonary hypertension (including load adaptation) agreed with clinical data as obtained in healthy volunteers and pulmonary hypertension patients. In chronic pulmonary hypertension, the model predicted right ventricular free wall hypertrophy, increased systolic pulmonary flow acceleration, and increased right ventricular isovolumic contraction and relaxation times. Furthermore, septal curvature decreased linearly with its transmural pressure difference. In conclusion, the TriSeg model enables realistic simulation of ventricular mechanics including interaction between left and right ventricular pump mechanics, dynamics of septal geometry, and myofiber mechanics in the three ventricular walls

    Forward modeling of standing kink modes in coronal loops. I. Synthetic views

    Get PDF
    Kink magnetohydrodynamic (MHD) waves are frequently observed in various magnetic structures of the solar atmosphere. They may contribute significantly to coronal heating and could be used as a tool to diagnose the solar plasma. In this study, we synthesize the Fe ix λ171.073 emission of a coronal loop supporting a standing kink MHD mode. The kink MHD wave solution of a plasma cylinder is mapped into a semi-torus structure to simulate a curved coronal loop. We decompose the solution into a quasi-rigid kink motion and a quadrupole term, which dominate the plasma inside and outside of the flux tube, respectively. At the loop edges, the line of sight integrates relatively more ambient plasma, and the background emission becomes significant. The plasma motion associated with the quadrupole term causes spectral line broadening and emission suppression. The periodic intensity suppression will modulate the integrated intensity and the effective loop width, which both exhibit oscillatory variations at half of the kink period. The quadrupole term can be directly observed as a pendular motion at the front view
    corecore